Crossref journal-article
Ovid Technologies (Wolters Kluwer Health)
Stroke (276)
Abstract

The transcranial color duplex sonography technique was applied to the vertebrobasilar-posterior system to provide normal data for clinical application. The intracranial posterior circulation was studied in 49 healthy volunteers (mean +/- SD age, 35 +/- 12 years) by a transcranial and suboccipital approach with a 2.0-MHz sector transducer of a computed sonography system. The posterior cerebral artery and the vertebrobasilar system were depicted clearly in the color Doppler mode. Pulsed Doppler signals could be recorded in the posterior cerebral (100%), basilar (92%), and vertebral arteries (89%). The following normal values were provided for all vessels: systolic peak, end-diastolic maximum, time-averaged, and time-averaged maximum velocities; resistance and pulsatility indexes; and a spectral broadening index. Mean +/- SD values were 45.9 +/- 9.6, 45.5 +/- 10.8, and 39.2 +/- 10.6 cm/sec for time-averaged maximum velocity, and 28.3 +/- 6.5, 30.6 +/- 7.2, and 24.7 +/- 8.4 cm/sec for time-averaged velocity in the posterior cerebral, basilar, and vertebral arteries, respectively. In a reproducibility study, duplex measurements of the posterior cerebral arteries were repeated in 27 subjects. The correlation between the two examiners was high (r = 0.56, p less than or equal to 0.0001 for time-averaged maximum velocity). Color duplex sonography of the vertebrobasilar-posterior system is a new, noninvasive, bedside investigative technique. It permits visualization of artery flow in real time, relating these to adjacent brain and cranial structures, as well as angle-corrected duplex measurement of "true" flow velocities at defined sites of the vessels. Thus, it will open new diagnostic possibilities in disorders of the posterior circulation.

Bibliography

Schöning, M., & Walter, J. (1992). Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults. Stroke, 23(9), 1280–1286.

Authors 2
  1. M Schöning (first)
  2. J Walter (additional)
References 0 Referenced 58

None

Dates
Type When
Created 14 years, 2 months ago (June 17, 2011, 4:08 p.m.)
Deposited 1 year, 3 months ago (May 12, 2024, 6:33 p.m.)
Indexed 11 months, 4 weeks ago (Aug. 21, 2024, 10:11 p.m.)
Issued 32 years, 11 months ago (Sept. 1, 1992)
Published 32 years, 11 months ago (Sept. 1, 1992)
Published Print 32 years, 11 months ago (Sept. 1, 1992)
Funders 0

None

@article{Sch_ning_1992, title={Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.}, volume={23}, ISSN={1524-4628}, url={http://dx.doi.org/10.1161/01.str.23.9.1280}, DOI={10.1161/01.str.23.9.1280}, number={9}, journal={Stroke}, publisher={Ovid Technologies (Wolters Kluwer Health)}, author={Schöning, M and Walter, J}, year={1992}, month=sep, pages={1280–1286} }