Crossref journal-article
Wiley
Medical Physics (311)
Abstract

The multi‐slice CT scanner refers to a special CT system equipped with a multiple‐row detector array to simultaneously collect data at different slice locations. The multi‐slice CT scanner has the capability of rapidly scanning large longitudinal (z) volume with high z‐axis resolution. It also presents new challenges and new characteristics. In this paper, we study the scan and reconstruction principles of the multi‐slice helical CT in general and the 4‐slice helical CT in particular. The multi‐slice helical computed tomography consists of the following three key components: the preferred helical pitches for efficient z sampling in data collection and better artifact control; the new helical interpolation algorithms to correct for fast simultaneous patient translation; and the z‐filtering reconstruction for providing multiple tradeoffs of the slice thickness, image noise and artifacts to suit for different application requirements. The concept of the preferred helical pitch is discussed with a newly proposed z sampling analysis. New helical reconstruction algorithms and z‐filtering reconstruction are developed for multi‐slice CT in general. Furthermore, the theoretical models of slice profile and image noise are established for multi‐slice helical CT. For 4‐slice helical CT in particular, preferred helical pitches are discussed. Special reconstruction algorithms are developed. Slice profiles, image noises, and artifacts of 4‐slice helical CT are studied and compared with single slice helical CT. The results show that the slice profile, image artifacts, and noise exhibit performance peaks or valleys at certain helical pitches in the multi‐slice CT, whereas in the single‐slice CT the image noise remains unchanged and the slice profile and image artifacts steadily deteriorate with helical pitch. The study indicates that the 4‐slice helical CT can provide equivalent image quality at 2 to 3 times the volume coverage speed of the single slice helical CT.

Bibliography

Hu, H. (1999). Multi‐slice helical CT: Scan and reconstruction. Medical Physics, 26(1), 5–18. Portico.

Authors 1
  1. Hui Hu (first)
References 24 Referenced 392
  1. I. Mori “Computerized tomographic apparatus utilizing a radiation source ” U.S. Patent No. 4 630 202 1986.
  2. H. Nishimura and O. Miyazaki “CT system for spirally scanning subject on a movable bed synchronized to x‐ray tube revolution ” U.S. Patent No. 4 789 929 1988.
  3. 10.1118/1.596464
  4. 10.1148/radiology.176.1.2353088
  5. 10.1148/radiology.185.1.1523331
  6. 10.1118/1.597706
  7. 10.1148/radiology.185.2.1410356
  8. 10.1148/radiographics.14.4.7938775
  9. J. S. Arenson R. Levinson and D. Freundlich “Dual slice scanner ” U.S. Patent No. 5 228 069 1993.
  10. 10.1118/1.597705
  11. L. Feldkamp L. Davis and J. Kress “Practical cone‐beam algorithm ” J. Opt. Soc. Am. 612–619 (1984). (10.1364/JOSAA.1.000612)
  12. 10.1002/sca.4950180807
  13. {'key': 'e_1_2_1_14_1', 'article-title': 'Helical‐scan computed tomography using cone‐beam projections,” in', 'author': 'Kudo H.', 'year': '1991', 'journal-title': 'IEEE NSS/MIC'} / IEEE NSS/MIC / Helical‐scan computed tomography using cone‐beam projections,” in by Kudo H. (1991)
  14. 10.1109/42.241876
  15. S. Schaller T. Flohr and P. Steffen “A new efficient Fourier‐reconstruction method for approximate image reconstruction in spiral cone‐beam CT at small cone‐angles. ” in SPIE International Symposium on Medical Imaging 1997. (10.1117/12.273987)
  16. H. Hu and N. Pelc “Systems methods and apparatus for reconstructing images in a CT system implementing a helical scan ” U.S. Patent No. 5 559 847 1996.
  17. H. Hu “Image reconstruction for a CT system implementing a four fan beam helical scan ” U.S. Patent No. 5 541 970 1996.
  18. 10.1118/1.598409
  19. H. Hu “Method and apparatus for multislice helical image reconstruction in a computer tomography system ” U.S. Patent No. 5 606 585 1997.
  20. {'key': 'e_1_2_1_21_1', 'first-page': '189', 'article-title': 'Helical reconstruction algorithm with user‐selectable section profile,” in', 'author': 'Hu H.', 'year': '1996', 'journal-title': 'RSNA'} / RSNA / Helical reconstruction algorithm with user‐selectable section profile,” in by Hu H. (1996)
  21. 10.1118/1.596607
  22. 10.1118/1.596950
  23. 10.1118/1.597306
  24. 10.1118/1.597774
Dates
Type When
Created 23 years ago (July 26, 2002, 10:01 a.m.)
Deposited 1 year, 11 months ago (Sept. 16, 2023, 4:22 a.m.)
Indexed 6 hours, 26 minutes ago (Aug. 23, 2025, 12:58 a.m.)
Issued 26 years, 7 months ago (Jan. 1, 1999)
Published 26 years, 7 months ago (Jan. 1, 1999)
Published Online 26 years, 7 months ago (Jan. 5, 1999)
Published Print 26 years, 7 months ago (Jan. 1, 1999)
Funders 0

None

@article{Hu_1999, title={Multi‐slice helical CT: Scan and reconstruction}, volume={26}, ISSN={2473-4209}, url={http://dx.doi.org/10.1118/1.598470}, DOI={10.1118/1.598470}, number={1}, journal={Medical Physics}, publisher={Wiley}, author={Hu, Hui}, year={1999}, month=jan, pages={5–18} }