Crossref journal-article
Wiley
Medical Physics (311)
Bibliography

Bottigli, U., Golosio, B., Masala, G. L., Oliva, P., Stumbo, S., Delogu, P., Fantacci, M. E., Abbene, L., Fauci, F., & Raso, G. (2006). Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy. Medical Physics, 33(9), 3469–3477. Portico.

Authors 10
  1. U. Bottigli (first)
  2. B. Golosio (additional)
  3. G. L. Masala (additional)
  4. P. Oliva (additional)
  5. S. Stumbo (additional)
  6. P. Delogu (additional)
  7. M. E. Fantacci (additional)
  8. L. Abbene (additional)
  9. F. Fauci (additional)
  10. G. Raso (additional)
References 9 Referenced 27
  1. 10.1118/1.1785891 / Med. Phys. / Direct analysis of molybdenum target generated x-ray spectra with a portable device by Stumbo (2004)
  2. CdTe http://www.amptek.com/cdte.html 2002
  3. 10.1088/0031-9155/47/22/304 / Phys. Med. Biol. / CdZnTe detector in mammographic x-ray spectroscopy by Miyajima (2002)
  4. 10.1118/1.1485975 / Med. Phys. / CdZnTe detector in diagnostic x-ray spectroscopy by Miyajima (2002)
  5. 10.1118/1.597953 / Med. Phys. / An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140kv by Boone (1997)
  6. 10.1118/1.596444 / Med. Phys. / On the measurement of half-value layer in filmscreen mammography by Wagner (1990)
  7. 10.1137/0111030 / J. Soc. Ind. Appl. Math. / An algorithm for least-squares estimation of nonlear parameters by Marquardt (1963)
  8. {'issue': '3', 'key': '10.1118/1.2229431-BIB8|rf8', 'first-page': '257', 'article-title': 'Spectroscopic performances of 16×16pixel CZT imaging hard X-ray detectors', 'volume': '119B', 'author': 'Del Sordo', 'year': '2004', 'journal-title': 'Nuovo Cimento Soc. Ital. Fis., B'} / Nuovo Cimento Soc. Ital. Fis., B / Spectroscopic performances of 16×16pixel CZT imaging hard X-ray detectors by Del Sordo (2004)
  9. K. Cranley B. Gilmore G. Fogarty L. Desponds Catalogue of diagnostic x-ray spectra and other data
Dates
Type When
Created 18 years, 11 months ago (Sept. 8, 2006, 7:36 p.m.)
Deposited 7 years ago (Aug. 4, 2018, 2:17 p.m.)
Indexed 1 year, 2 months ago (May 30, 2024, 10:59 p.m.)
Issued 18 years, 11 months ago (Aug. 30, 2006)
Published 18 years, 11 months ago (Aug. 30, 2006)
Published Online 18 years, 11 months ago (Aug. 30, 2006)
Published Print 18 years, 11 months ago (Aug. 30, 2006)
Funders 0

None

@article{Bottigli_2006, title={Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy: Mammographic x-ray spectra with CZT and CdTe detectors}, volume={33}, ISSN={0094-2405}, url={http://dx.doi.org/10.1118/1.2229431}, DOI={10.1118/1.2229431}, number={9}, journal={Medical Physics}, publisher={Wiley}, author={Bottigli, U. and Golosio, B. and Masala, G. L. and Oliva, P. and Stumbo, S. and Delogu, P. and Fantacci, M. E. and Abbene, L. and Fauci, F. and Raso, G.}, year={2006}, month=aug, pages={3469–3477} }