Abstract
SUMMARYThe scanning electron microscope (SEM) is usually operated with a beam voltage, V0, in the range of 10–30 kV, even though many early workers had suggested the use of lower voltages to increase topographic contrast and to reduce specimen charging and beam damage. The chief reason for this contradiction is poor instrumental performance when V0=1–3 kV, The problems include low source brightness, greater defocusing due to chromatic aberration greater sensitivity to stray fields, and difficulty in collecting the secondary electron signal. Responding to the needs of the semiconductor industry, which uses low V0 to reduce beam damage, considerable efforts have been made to overcome these problems. The resulting equipment has greatly improved performance at low kV and substantially removes the practical deterrents to operation in this mode. This paper reviews the advantages of low voltage operation, recent progress in instrumentation and describes a prototype instrument designed and built for optimum performance at 1 kV. Other limitations to high resolution topographic imaging such as surface contamination, the de‐localized nature of the inelastic scattering event and radiation damage are also discussed.
References
129
Referenced
87
{'key': 'e_1_2_1_2_1', 'first-page': '17', 'article-title': 'High resolution shadowing for electron microscopy by sputter deposition', 'volume': '12', 'author': 'Adachi K.', 'year': '1983', 'journal-title': 'Ultramicrosc.'}
/ Ultramicrosc. / High resolution shadowing for electron microscopy by sputter deposition by Adachi K. (1983)10.1002/sca.4950050106
{'key': 'e_1_2_1_4_1', 'first-page': '159', 'article-title': 'High resolution SEM of cultured cells: preparatory procedures', 'author': 'Arro E.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / High resolution SEM of cultured cells: preparatory procedures by Arro E. (1981)10.1088/0022-3735/11/7/028
{'key': 'e_1_2_1_6_1', 'first-page': '489', 'article-title': 'Single‐crystal aluminates. A new generation of scintillators for scanning electron microscopes and transparent screens in electron optical devices', 'author': 'Autrata R.', 'year': '1983', 'journal-title': 'SEM'}
/ SEM / Single‐crystal aluminates. A new generation of scintillators for scanning electron microscopes and transparent screens in electron optical devices by Autrata R. (1983)10.1111/j.1365-2818.1981.tb01305.x
{'key': 'e_1_2_1_8_1', 'first-page': '121', 'article-title': 'Comparison and evaluation of specimens for resolution standard', 'author': 'Ballard D.B.', 'year': '1972', 'journal-title': 'IITRI/SEM'}
/ IITRI/SEM / Comparison and evaluation of specimens for resolution standard by Ballard D.B. (1972){'key': 'e_1_2_1_9_1', 'first-page': '473', 'article-title': 'Voltage measurement in the scanning electron microscope', 'volume': '1970', 'author': 'Banbury J.R.', 'year': '1970', 'journal-title': 'IITRI/SEM'}
/ IITRI/SEM / Voltage measurement in the scanning electron microscope by Banbury J.R. (1970)10.1016/0304-3991(76)90054-1
10.1016/S0304-3991(81)80209-4
10.1007/BF01375256
- Boyde A.(1971)A review of problems of interpretation of the SEM image with special regard to methods of specimen preparation.IITRI/SEM1971(Part I) 1–8.
{'key': 'e_1_2_1_14_1', 'first-page': '1487', 'article-title': 'Quantitative investigations in semiconductor devices by electron beam induced current mode: a review', 'author': 'Bresse J.F.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / Quantitative investigations in semiconductor devices by electron beam induced current mode: a review by Bresse J.F. (1982){'key': 'e_1_2_1_15_1', 'first-page': '9', 'article-title': 'Recent advances in scanning electron microscopy with lanthanum hexaboride cathodes', 'volume': '1', 'author': 'Broers A.N.', 'year': '1974', 'journal-title': 'IITRI/SEM'}
/ IITRI/SEM / Recent advances in scanning electron microscopy with lanthanum hexaboride cathodes by Broers A.N. (1974)10.1016/0304-3991(82)90283-2
10.1126/science.125922
- Buchanan R.(1982)New SEM lens give sharpest micrographs yet.Industrial Research and Development August 92–95.
- Buchanan R.(1983)The scanning electron microscope for semiconductor application.Microelectronic Manufacturing and Testing February 22–24.
10.1111/j.1365-2818.1973.tb03844.x
10.1007/BF00549753
- Cliff G.&Kenway P.B.(1982)The effect of spherical aberration in probe‐forming lenses on probe size image resolution and X‐ray spatial resolution in scanning transmission electron microscopy.Microbeam Analysis 107–110.
10.1111/j.1365-2818.1978.tb02454.x
{'key': 'e_1_2_1_24_1', 'first-page': '225', 'volume-title': 'Progress in Optics', 'author': 'Crewe A.V.', 'year': '1973'}
/ Progress in Optics by Crewe A.V. (1973)10.1063/1.1683435
10.1063/1.1685116
10.1016/0304-3991(76)90037-1
10.1126/science.168.3937.1338
10.1016/S0304-3991(76)91487-X
10.1002/sca.4950030405
10.1002/sca.4950040402
- Everhart T.E.(1970)Contrast and resolution in the scanning electron microscope.Third Annual Cambridge Steroscan Colloquium Chicago..
10.1088/0950-7671/37/7/307
10.1080/00207215908937191
{'key': 'e_1_2_1_35_1', 'first-page': '127', 'article-title': 'Electric effects in contamination and electron beam etching', 'author': 'Fourie J.T.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / Electric effects in contamination and electron beam etching by Fourie J.T. (1981)10.1111/j.1365-2818.1975.tb04062.x
10.1016/S0022-5320(71)80118-1
{'key': 'e_1_2_1_38_1', 'first-page': '205', 'volume-title': 'Physical Aspects of Electron Microscopy and Microbeam Analysis', 'author': 'Glaeser R.M.', 'year': '1975'}
/ Physical Aspects of Electron Microscopy and Microbeam Analysis by Glaeser R.M. (1975){'key': 'e_1_2_1_39_1', 'first-page': '751', 'article-title': 'Contribution of scanning electron microscopy to viewing internal cell structure', 'author': 'Haggis G.H.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / Contribution of scanning electron microscopy to viewing internal cell structure by Haggis G.H. (1982)10.1111/j.1365-2818.1979.tb00174.x
10.1111/j.1365-2818.1983.tb04271.x
{'key': 'e_1_2_1_42_1', 'first-page': '591', 'article-title': 'Understanding and using field emission sources', 'author': 'Hainfeld J.F.', 'year': '1977', 'journal-title': 'SEM'}
/ SEM / Understanding and using field emission sources by Hainfeld J.F. (1977){'key': 'e_1_2_1_43_1', 'first-page': '253', 'article-title': 'Spatial distribution of secondaries released by backscattered electrons in silicon and gold for 20–70 keV primary energy', 'author': 'Hasselbach F.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / Spatial distribution of secondaries released by backscattered electrons in silicon and gold for 20–70 keV primary energy by Hasselbach F. (1982){'key': 'e_1_2_1_44_1', 'first-page': '467', 'article-title': 'An imaging secondary electron detector for the scanning electron microscope', 'author': 'Hasselbach F.', 'year': '1983', 'journal-title': 'IITRI/SEM'}
/ IITRI/SEM / An imaging secondary electron detector for the scanning electron microscope by Hasselbach F. (1983){'key': 'e_1_2_1_45_1', 'first-page': '456', 'article-title': 'The single‐pole lens as a scanning electron microscope objective', 'author': 'Hill R.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / The single‐pole lens as a scanning electron microscope objective by Hill R. (1982){'key': 'e_1_2_1_46_1', 'first-page': '351', 'article-title': 'Electron optical properties of low energy field emission gun in the energy range from 100 to 2000 eV', 'author': 'Ichinokawa T.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / Electron optical properties of low energy field emission gun in the energy range from 100 to 2000 eV by Ichinokawa T. (1982){'key': 'e_1_2_1_47_1', 'first-page': '92', 'article-title': 'Determination of non‐localization of the inelastic scattering of electrons by electron microscopy', 'volume': '41', 'author': 'Isaacson M.', 'year': '1974', 'journal-title': 'Optik'}
/ Optik / Determination of non‐localization of the inelastic scattering of electrons by electron microscopy by Isaacson M. (1974)10.1111/j.1365-2818.1984.tb00532.x
{'key': 'e_1_2_1_49_1', 'first-page': '496', 'article-title': 'Low‐loss images in a STEM/TEM microscope', 'volume': '34', 'author': 'Joy D.C.', 'year': '1976', 'journal-title': 'EMSA'}
/ EMSA / Low‐loss images in a STEM/TEM microscope by Joy D.C. (1976)10.1111/j.1365-2818.1982.tb00442.x
{'key': 'e_1_2_1_51_1', 'first-page': '507', 'article-title': 'Electron beam effects on microelectronic devices', 'author': 'Keery W.J.', 'year': '1976', 'journal-title': 'IITRI/SEM'}
/ IITRI/SEM / Electron beam effects on microelectronic devices by Keery W.J. (1976)10.1111/j.1365-2818.1983.tb04267.x
{'issue': '4', 'key': 'e_1_2_1_53_1', 'first-page': '2', 'article-title': 'An approach to microanalysis with the electron microscope', 'volume': '10', 'author': 'Koike H.', 'year': '1973', 'journal-title': 'Jeol News'}
/ Jeol News / An approach to microanalysis with the electron microscope by Koike H. (1973){'issue': '3', 'key': 'e_1_2_1_54_1', 'first-page': '20', 'article-title': 'High resolution scanning device for the JEM‐100B electron microscope', 'volume': '9', 'author': 'Koike H.', 'year': '1971', 'journal-title': 'Jeol News'}
/ Jeol News / High resolution scanning device for the JEM‐100B electron microscope by Koike H. (1971){'key': 'e_1_2_1_55_1', 'first-page': '138', 'article-title': 'An application of strongly excited objective lens to low loss image', 'volume': '33', 'author': 'Kokubo Y.', 'year': '1975', 'journal-title': 'EMSA'}
/ EMSA / An application of strongly excited objective lens to low loss image by Kokubo Y. (1975){'key': 'e_1_2_1_56_1', 'first-page': '201', 'volume-title': 'Microscopie Electronique', 'author': 'Kosuge T.', 'year': '1970'}
/ Microscopie Electronique by Kosuge T. (1970)10.1063/1.328746
{'key': 'e_1_2_1_58_1', 'first-page': '522', 'article-title': 'A field emission probe forming system with a magnetic pre‐accelerator lens', 'volume': '34', 'author': 'Kuo H.P.', 'year': '1976', 'journal-title': 'EMSA'}
/ EMSA / A field emission probe forming system with a magnetic pre‐accelerator lens by Kuo H.P. (1976)10.1002/sca.4950050104
{'key': 'e_1_2_1_60_1', 'first-page': '47', 'article-title': 'Monte Carlo calculation for electron microscopy, microanalysis, and microlithography', 'author': 'Kyser D.F.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / Monte Carlo calculation for electron microscopy, microanalysis, and microlithography by Kyser D.F. (1981)10.1109/JRPROC.1937.228419
{'key': 'e_1_2_1_62_1', 'first-page': '537', 'article-title': 'Electron channelling effect on secondary electron image contrast', 'author': 'Gressus C.', 'year': '1983', 'journal-title': 'SEM'}
/ SEM / Electron channelling effect on secondary electron image contrast by Gressus C. (1983)10.1111/j.1365-2818.1975.tb03900.x
{'key': 'e_1_2_1_64_1', 'first-page': '245', 'article-title': 'An improved scanning electron microscope for opaque specimens', 'volume': '100', 'author': 'McMullan D.', 'year': '1953', 'journal-title': 'Proc. IEE II'}
/ Proc. IEE II / An improved scanning electron microscope for opaque specimens by McMullan D. (1953){'key': 'e_1_2_1_65_1', 'first-page': '1507', 'article-title': 'Effects of electron beam testing on the short channel metal oxide semiconductor characteristics', 'author': 'Miyoshi M.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / Effects of electron beam testing on the short channel metal oxide semiconductor characteristics by Miyoshi M. (1982)10.1007/978-3-642-81516-4_5
10.1063/1.329366
{'key': 'e_1_2_1_68_1', 'first-page': '389', 'article-title': 'High performance analytical scanning electron microscope provided with C‐F mini lens and zoom condenser lens system', 'author': 'Nakagawa S.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / High performance analytical scanning electron microscope provided with C‐F mini lens and zoom condenser lens system by Nakagawa S. (1982)10.1002/sca.4950010103
- Nomura S. Komoda T. Kamiryo T.&Nakaizumi Y.(1973)Stable field emission gun with an electronic feedback system.IITRI/SEM1973 65–72.
10.1088/0022-3735/2/8/440
{'key': 'e_1_2_1_72_1', 'volume-title': 'The Scanning Electron Microscope', 'author': 'Oatley C.W.', 'year': '1972'}
/ The Scanning Electron Microscope by Oatley C.W. (1972)10.1088/0022-3735/8/12/018
10.1063/1.331666
10.1088/0022-3735/16/4/015
10.1080/00207215708937060
{'key': 'e_1_2_1_77_1', 'first-page': '181', 'volume-title': 'Advances in Electronics and Electron Physics', 'author': 'Oatley C.W.', 'year': '1965'}
/ Advances in Electronics and Electron Physics by Oatley C.W. (1965){'key': 'e_1_2_1_78_1', 'first-page': '253', 'article-title': 'Brightness of the hot cathode electron gun at high emission densities', 'volume': '27', 'author': 'Ohshita A.', 'year': '1978', 'journal-title': 'J. Electron. Microsc.'}
/ J. Electron. Microsc. / Brightness of the hot cathode electron gun at high emission densities by Ohshita A. (1978)10.1016/S0304-3991(78)80026-6
- Pawley J.B.(1972)Charging artifacts in the scanning electron microscope.IITRI/SEM1972 153–160.
- Pawley J.B.(1974)Performance of SEM scintillator materials.IITRI/SEM1974 27–34.
{'key': 'e_1_2_1_82_1', 'article-title': 'Strategy for locating and eliminating sources of mains frequency magnetic stray field', 'author': 'Pawley J.B.', 'year': '1984', 'journal-title': 'Scanning'}
/ Scanning / Strategy for locating and eliminating sources of mains frequency magnetic stray field by Pawley J.B. (1984){'key': 'e_1_2_1_83_1', 'first-page': '683', 'article-title': 'Preliminary studies of coated complementary freeze‐fractured yeast membranes viewed directly in the SEM', 'author': 'Pawley J.B.', 'year': '1978', 'journal-title': 'SEM'}
/ SEM / Preliminary studies of coated complementary freeze‐fractured yeast membranes viewed directly in the SEM by Pawley J.B. (1978)10.1002/sca.4950030316
10.1111/j.1365-2818.1978.tb01163.x
{'key': 'e_1_2_1_86_1', 'first-page': '383', 'article-title': 'A low voltage SEM optimized for high resolution topographical imaging', 'author': 'Pawley J.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / A low voltage SEM optimized for high resolution topographical imaging by Pawley J. (1982)-
Pawley J.B.&Winters M.P.(1983)Low voltage SEM. 41st Ann. Proc. EMSA 488–492.
(
10.1017/S0424820100076160
) 10.1088/0950-7671/42/2/305
{'key': 'e_1_2_1_89_1', 'first-page': '133', 'article-title': 'Scanning electron microscopy at macromolecular resolution in low energy mode on biological specimens coated with ultra thin metal films', 'author': 'Peters K.‐R.', 'year': '1979', 'journal-title': 'SEM'}
/ SEM / Scanning electron microscopy at macromolecular resolution in low energy mode on biological specimens coated with ultra thin metal films by Peters K.‐R. (1979){'key': 'e_1_2_1_90_1', 'first-page': '1359', 'article-title': 'Conditions required for high quality high magnification images in secondary electron‐I scanning electron microscopy', 'author': 'Peters K.‐R.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / Conditions required for high quality high magnification images in secondary electron‐I scanning electron microscopy by Peters K.‐R. (1982){'key': 'e_1_2_1_91_1', 'first-page': '606', 'article-title': 'Macromolecular structures of biological specimens are not obscured by controlled osmium impregnation', 'volume': '1983', 'author': 'Peters K.‐R.', 'year': '1983', 'journal-title': 'Proc. EMSA.'}
/ Proc. EMSA. / Macromolecular structures of biological specimens are not obscured by controlled osmium impregnation by Peters K.‐R. (1983)10.1083/jcb.96.1.265
- Pfeiffer H.C.(1972)Basic limitations of probe forming systems due to electron‐electron interactions.IITRI/SEM1972 113–120.
{'key': 'e_1_2_1_94_1', 'first-page': '435', 'article-title': 'Probe forming systems', 'author': 'Pfeiffer H.C.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / Probe forming systems by Pfeiffer H.C. (1982)10.1117/12.7973081
-
Pomposo T.F.&Coates V.J.(1982)Computerized electron‐beam line‐width measuring and inspection: a new tool.Silicon Processing 501–508.
(
10.1520/STP36188S
) 10.1002/sca.4950010102
{'key': 'e_1_2_1_98_1', 'first-page': '111', 'article-title': 'Electron—specimen interactions', 'author': 'Reimer L.', 'year': '1979', 'journal-title': 'SEM'}
/ SEM / Electron—specimen interactions by Reimer L. (1979)10.1002/sca.4950020406
{'key': 'e_1_2_1_100_1', 'first-page': '379', 'article-title': 'A field emission SEM controlled by microprocessor', 'author': 'Saito S.', 'year': '1982', 'journal-title': 'Proc. Europ. Reg. Conf. Electron Microscopy'}
/ Proc. Europ. Reg. Conf. Electron Microscopy / A field emission SEM controlled by microprocessor by Saito S. (1982){'key': 'e_1_2_1_101_1', 'first-page': '7', 'article-title': 'Three dimensional observation on muscular tissues', 'author': 'Sawada H.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / Three dimensional observation on muscular tissues by Sawada H. (1981)- Seiler H.(1976)Determination of the ‘information depth’ in the SEM.IITRI/SEM1976 9–16.
- Shaffner T.J.&Hearle J.W.S.(1976)Recent advances in understanding specimen charging.IITRI/SEM1976 61–70.
{'key': 'e_1_2_1_104_1', 'first-page': '68', 'article-title': 'Field emission SEM using strongly excited objective lens', 'volume': '38', 'author': 'Tamura N.', 'year': '1980', 'journal-title': 'EMSA'}
/ EMSA / Field emission SEM using strongly excited objective lens by Tamura N. (1980)10.1016/S0074-7696(08)62308-6
{'key': 'e_1_2_1_106_1', 'first-page': '1', 'article-title': 'Demonstration of intracellular structure by high resolution scanning electron microscopy', 'author': 'Tanaka K.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / Demonstration of intracellular structure by high resolution scanning electron microscopy by Tanaka K. (1981)- Thornley R.F.M.(1960)Recent developments in scanning electron microscopy. In:Proc. Eur. Reg. Conf. Elect. Microsc. Delft(Ed. byA. L.HouwinkandB. J.Spit) pp.173–176.
{'key': 'e_1_2_1_108_1', 'first-page': '70', 'article-title': 'Low acceleration scanning electron microscope', 'volume': '38', 'author': 'Todokoro H.', 'year': '1980', 'journal-title': 'EMSA'}
/ EMSA / Low acceleration scanning electron microscope by Todokoro H. (1980){'key': 'e_1_2_1_109_1', 'first-page': '561', 'article-title': 'Stroboscopic scanning electron microscope with 1 keV electrons', 'author': 'Todokoro H.', 'year': '1983', 'journal-title': 'SEM'}
/ SEM / Stroboscopic scanning electron microscope with 1 keV electrons by Todokoro H. (1983)10.1111/j.1365-2818.1983.tb04551.x
{'key': 'e_1_2_1_111_1', 'first-page': '343', 'article-title': 'Micron and submicron lithography for VSLI device fabrication', 'author': 'Varnell G.L.', 'year': '1981', 'journal-title': 'SEM'}
/ SEM / Micron and submicron lithography for VSLI device fabrication by Varnell G.L. (1981){'key': 'e_1_2_1_112_1', 'first-page': '897', 'article-title': 'Signal mixing techniques in scanning electron microscopy', 'author': 'Volbert B.', 'year': '1982', 'journal-title': 'SEM'}
/ SEM / Signal mixing techniques in scanning electron microscopy by Volbert B. (1982){'key': 'e_1_2_1_113_1', 'first-page': '233', 'article-title': 'True surface topography: the need for a signal mixing', 'author': 'Volbert B.', 'year': '1982', 'journal-title': 'EM'}
/ EM / True surface topography: the need for a signal mixing by Volbert B. (1982){'key': 'e_1_2_1_114_1', 'first-page': '1', 'article-title': 'Advantages of two opposite Everhart‐Thornley detectors in SEM', 'author': 'Volbert B.', 'year': '1980', 'journal-title': 'SEM'}
/ SEM / Advantages of two opposite Everhart‐Thornley detectors in SEM by Volbert B. (1980){'key': 'e_1_2_1_115_1', 'first-page': '358', 'article-title': 'Contamination and reverse contamination at low temperature', 'volume': '37', 'author': 'Voreades D.', 'year': '1979', 'journal-title': 'EMSA'}
/ EMSA / Contamination and reverse contamination at low temperature by Voreades D. (1979){'key': 'e_1_2_1_116_1', 'first-page': '558', 'article-title': 'Contamination at low temperature', 'volume': '35', 'author': 'Wall J.', 'year': '1977', 'journal-title': 'EMSA'}
/ EMSA / Contamination at low temperature by Wall J. (1977)10.1016/S0304-3991(78)80003-5
- Wells O.C.(1974a)Resolution of the topographic image in the SEM.IITRI/SEM1974 1–8.
{'key': 'e_1_2_1_119_1', 'volume-title': 'Scanning Electron Microscopy', 'author': 'Wells O.C.', 'year': '1974'}
/ Scanning Electron Microscopy by Wells O.C. (1974)10.1002/sca.4950010106
10.1002/sca.4950020402
10.1063/1.1654916
- Welter L.M.&Coates V.J.(1974)High resolution scanning electron microscopy at low accelerating voltages.IITRI/SEM1974 59–66.
- Welter L.M.&McKee A.N.(1972)Observations on uncoated nonconducting or thermally sensitive specimens using a fast scanning field emission source SEM.IITRI/SEM1972 161–168.
- Wiesner J.C.(1973)Characteristics and applications of pointed cathodes in scanning electron microscopes.IITRI/SEM1973 33–40.
10.1063/1.1662526
10.1111/j.1365-2818.1964.tb00530.x
{'key': 'e_1_2_1_128_1', 'first-page': '825', 'article-title': 'Expectations and limitations of low voltage electron microscopy', 'volume': '14', 'author': 'Wilska A.P.', 'year': '1965', 'journal-title': 'Lab. Invest.'}
/ Lab. Invest. / Expectations and limitations of low voltage electron microscopy by Wilska A.P. (1965)- Yamazaki S. Kawawoto H. Saburi K. Nakatsuka H.&Buchanan R.(1983)Improvement in SEM gun brightness at low kV using an intermediate extraction electrode.SEM1983.
10.1116/1.571166
Dates
Type | When |
---|---|
Created | 14 years ago (Aug. 2, 2011, 1:22 p.m.) |
Deposited | 1 year, 10 months ago (Oct. 19, 2023, 11:26 p.m.) |
Indexed | 1 year ago (Aug. 6, 2024, 5:59 a.m.) |
Issued | 40 years, 10 months ago (Oct. 1, 1984) |
Published | 40 years, 10 months ago (Oct. 1, 1984) |
Published Online | 14 years ago (Aug. 2, 2011) |
Published Print | 40 years, 10 months ago (Oct. 1, 1984) |
@article{Pawley_1984, title={Low voltage scanning electron microscopy}, volume={136}, ISSN={1365-2818}, url={http://dx.doi.org/10.1111/j.1365-2818.1984.tb02545.x}, DOI={10.1111/j.1365-2818.1984.tb02545.x}, number={1}, journal={Journal of Microscopy}, publisher={Wiley}, author={Pawley, James}, year={1984}, month=oct, pages={45–68} }