Crossref journal-article
AIP Publishing
Review of Scientific Instruments (317)
Abstract

The cable capacitance in cryogenic and high vacuum applications of quartz tuning forks imposes severe constraints on the bandwidth and noise performance of the measurement. We present a single stage low noise transimpedance amplifier with a bandwidth exceeding 1 MHz and provide an in-depth analysis of the dependence of the amplifier parameters on the cable capacitance.

Bibliography

Kleinbaum, E., & Csáthy, G. A. (2012). Note: A transimpedance amplifier for remotely located quartz tuning forks. Review of Scientific Instruments, 83(12).

Authors 2
  1. Ethan Kleinbaum (first)
  2. Gábor A. Csáthy (additional)
References 26 Referenced 10
  1. 10.1063/1.113340 / Appl. Phys. Lett. (1995)
  2. 10.1063/1.365936 / J. Appl. Phys. (1997)
  3. 10.1007/s10909-006-9279-4 / J. Low Temp. Phys. (2007)
  4. 10.1063/1.3586766 / Rev. Sci. Instrum. (2011)
  5. 10.1016/S0956-5663(01)00249-4 / Biosens. Bioelectron. (2002)
  6. 10.1063/1.122835 / Appl. Phys. Lett. (1998)
  7. 10.1063/1.1149842 / Rev. Sci. Instrum. (1999)
  8. 10.1063/1.1150521 / Rev. Sci. Instrum. (2000)
  9. 10.1063/1.2804165 / Rev. Sci. Instrum. (2007)
  10. 10.1063/1.2436651 / Appl. Phys. Lett. (2007)
  11. 10.1063/1.2431793 / Rev. Sci. Instrum. (2007)
  12. 10.1007/s10909-007-9584-6 / J. Low Temp. Phys. (2008)
  13. 10.1063/1.3499293 / Appl. Phys. Lett. (2010)
  14. 10.1103/PhysRevB.84.125409 / Phys. Rev. B (2011)
  15. 10.1063/1.1623012 / Appl. Phys. Lett. (2003)
  16. 10.1063/1.1846156 / Appl. Phys. Lett. (2005)
  17. 10.1063/1.2830937 / Rev. Sci. Instrum. (2008)
  18. 10.1063/1.1487890 / Rev. Sci. Instrum. (2002)
  19. 10.1063/1.1431256 / Rev. Sci. Instrum. (2002)
  20. 10.1063/1.1753104 / Rev. Sci. Instrum. (2004)
  21. 10.1063/1.2970944 / Rev. Sci. Instrum. (2008)
  22. 10.1088/1742-6596/150/1/012016 / J. Phys.: Conf. Ser. (2009)
  23. {'key': '2023070401473958500_c23'}
  24. 10.1063/1.2743166 / Rev. Sci. Instrum. (2007)
  25. 10.1063/1.1150691 / Rev. Sci. Instrum. (2000)
  26. 10.1063/1.1777386 / Rev. Sci. Instrum. (2004)
Dates
Type When
Created 12 years, 8 months ago (Dec. 4, 2012, 4:01 a.m.)
Deposited 2 years, 1 month ago (July 3, 2023, 9:58 p.m.)
Indexed 3 weeks, 3 days ago (July 30, 2025, 7 a.m.)
Issued 12 years, 8 months ago (Dec. 1, 2012)
Published 12 years, 8 months ago (Dec. 1, 2012)
Published Online 12 years, 8 months ago (Dec. 3, 2012)
Published Print 12 years, 8 months ago (Dec. 1, 2012)
Funders 1
  1. U.S. Department of Energy 10.13039/100000015

    Region: Americas

    gov (National government)

    Labels8
    1. Energy Department
    2. Department of Energy
    3. United States Department of Energy
    4. ENERGY.GOV
    5. US Department of Energy
    6. USDOE
    7. DOE
    8. USADOE
    Awards1
    1. DE-SC0006671

@article{Kleinbaum_2012, title={Note: A transimpedance amplifier for remotely located quartz tuning forks}, volume={83}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.4769271}, DOI={10.1063/1.4769271}, number={12}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Kleinbaum, Ethan and Csáthy, Gábor A.}, year={2012}, month=dec }