Abstract
The wavelength shift with pressure of the ruby R1 fluorescence line (Δλ) has been calibrated in the diamond-window pressure cell from 0.06 to 1 Mbar. This was done by simultaneously making specific volume measurements of four metals (Cu, Mo, Ag, and Pd) and referring these results to isothermal equations of state derived from shock-wave experiments. The result is P (Mbar) = (19.04/5) {[(λ0+Δλ)/λ0]5−1}, where λ0 is the wavelength measured at 1 bar.
References
13
Referenced
2,079
{'key': '2024020420550579600_r1', 'first-page': '509', 'volume': '75', 'year': '1976', 'journal-title': 'Carnegie Inst. Washington Yearb.'}
/ Carnegie Inst. Washington Yearb. (1976)10.1126/science.191.4229.851
/ Science (1976){'key': '2024020420550579600_r3'}
10.1063/1.321957
/ J. Appl. Phys. (1975){'key': '2024020420550579600_r5', 'first-page': '4867', 'volume': '11', 'year': '1976', 'journal-title': 'J. Appl. Phys.'}
/ J. Appl. Phys. (1976){'key': '2024020420550579600_r6', 'first-page': '147', 'volume': '326', 'year': '1971', 'journal-title': 'Nat. Bur. Stand. (U.S.) Spec. Publ.'}
/ Nat. Bur. Stand. (U.S.) Spec. Publ. (1971)10.1063/1.1718703
/ Rev. Sci. Instrum. (1964){'key': '2024020420550579600_r8', 'first-page': '824', 'volume': '75', 'year': '1976', 'journal-title': 'Carnegie Inst. Washington Yearb.'}
/ Carnegie Inst. Washington Yearb. (1976)10.1063/1.1720525
/ Rev. Sci. Instrum. (1967)10.1016/S0081-1947(08)60724-9
/ Solid State Phys. (1958){'key': '2024020420550579600_r11', 'first-page': '4659', 'volume': '11', 'year': '1975', 'journal-title': 'J. Appl. Phys.'}
/ J. Appl. Phys. (1975){'key': '2024020420550579600_r12', 'first-page': '929', 'volume': '12', 'year': '1971', 'journal-title': 'J. Appl. Mech. Tech. Phys. (USSR)'}
/ J. Appl. Mech. Tech. Phys. (USSR) (1971){'key': '2024020420550579600_r13', 'first-page': '321', 'volume': '326', 'year': '1971', 'journal-title': 'Nat. Bur. Stand. (U.S.) Spec. Publ.'}
/ Nat. Bur. Stand. (U.S.) Spec. Publ. (1971)
Dates
Type | When |
---|---|
Created | 22 years, 6 months ago (Feb. 14, 2003, 4:46 p.m.) |
Deposited | 1 year, 6 months ago (Feb. 4, 2024, 3:55 p.m.) |
Indexed | 6 days, 18 hours ago (Aug. 19, 2025, 6:22 a.m.) |
Issued | 47 years, 2 months ago (June 1, 1978) |
Published | 47 years, 2 months ago (June 1, 1978) |
Published Print | 47 years, 2 months ago (June 1, 1978) |
@article{Mao_1978, title={Specific volume measurements of Cu, Mo, Pd, and Ag and calibration of the ruby R1 fluorescence pressure gauge from 0.06 to 1 Mbar}, volume={49}, ISSN={1089-7550}, url={http://dx.doi.org/10.1063/1.325277}, DOI={10.1063/1.325277}, number={6}, journal={Journal of Applied Physics}, publisher={AIP Publishing}, author={Mao, H. K. and Bell, P. M. and Shaner, J. W. and Steinberg, D. J.}, year={1978}, month=jun, pages={3276–3283} }