Crossref journal-article
AIP Publishing
Journal of Applied Physics (317)
Abstract

The wavelength shift with pressure of the ruby R1 fluorescence line (Δλ) has been calibrated in the diamond-window pressure cell from 0.06 to 1 Mbar. This was done by simultaneously making specific volume measurements of four metals (Cu, Mo, Ag, and Pd) and referring these results to isothermal equations of state derived from shock-wave experiments. The result is P (Mbar) = (19.04/5) {[(λ0+Δλ)/λ0]5−1}, where λ0 is the wavelength measured at 1 bar.

Bibliography

Mao, H. K., Bell, P. M., Shaner, J. W., & Steinberg, D. J. (1978). Specific volume measurements of Cu, Mo, Pd, and Ag and calibration of the ruby R1 fluorescence pressure gauge from 0.06 to 1 Mbar. Journal of Applied Physics, 49(6), 3276–3283.

Authors 4
  1. H. K. Mao (first)
  2. P. M. Bell (additional)
  3. J. W. Shaner (additional)
  4. D. J. Steinberg (additional)
References 13 Referenced 2,079
  1. {'key': '2024020420550579600_r1', 'first-page': '509', 'volume': '75', 'year': '1976', 'journal-title': 'Carnegie Inst. Washington Yearb.'} / Carnegie Inst. Washington Yearb. (1976)
  2. 10.1126/science.191.4229.851 / Science (1976)
  3. {'key': '2024020420550579600_r3'}
  4. 10.1063/1.321957 / J. Appl. Phys. (1975)
  5. {'key': '2024020420550579600_r5', 'first-page': '4867', 'volume': '11', 'year': '1976', 'journal-title': 'J. Appl. Phys.'} / J. Appl. Phys. (1976)
  6. {'key': '2024020420550579600_r6', 'first-page': '147', 'volume': '326', 'year': '1971', 'journal-title': 'Nat. Bur. Stand. (U.S.) Spec. Publ.'} / Nat. Bur. Stand. (U.S.) Spec. Publ. (1971)
  7. 10.1063/1.1718703 / Rev. Sci. Instrum. (1964)
  8. {'key': '2024020420550579600_r8', 'first-page': '824', 'volume': '75', 'year': '1976', 'journal-title': 'Carnegie Inst. Washington Yearb.'} / Carnegie Inst. Washington Yearb. (1976)
  9. 10.1063/1.1720525 / Rev. Sci. Instrum. (1967)
  10. 10.1016/S0081-1947(08)60724-9 / Solid State Phys. (1958)
  11. {'key': '2024020420550579600_r11', 'first-page': '4659', 'volume': '11', 'year': '1975', 'journal-title': 'J. Appl. Phys.'} / J. Appl. Phys. (1975)
  12. {'key': '2024020420550579600_r12', 'first-page': '929', 'volume': '12', 'year': '1971', 'journal-title': 'J. Appl. Mech. Tech. Phys. (USSR)'} / J. Appl. Mech. Tech. Phys. (USSR) (1971)
  13. {'key': '2024020420550579600_r13', 'first-page': '321', 'volume': '326', 'year': '1971', 'journal-title': 'Nat. Bur. Stand. (U.S.) Spec. Publ.'} / Nat. Bur. Stand. (U.S.) Spec. Publ. (1971)
Dates
Type When
Created 22 years, 6 months ago (Feb. 14, 2003, 4:46 p.m.)
Deposited 1 year, 6 months ago (Feb. 4, 2024, 3:55 p.m.)
Indexed 6 days, 18 hours ago (Aug. 19, 2025, 6:22 a.m.)
Issued 47 years, 2 months ago (June 1, 1978)
Published 47 years, 2 months ago (June 1, 1978)
Published Print 47 years, 2 months ago (June 1, 1978)
Funders 0

None

@article{Mao_1978, title={Specific volume measurements of Cu, Mo, Pd, and Ag and calibration of the ruby R1 fluorescence pressure gauge from 0.06 to 1 Mbar}, volume={49}, ISSN={1089-7550}, url={http://dx.doi.org/10.1063/1.325277}, DOI={10.1063/1.325277}, number={6}, journal={Journal of Applied Physics}, publisher={AIP Publishing}, author={Mao, H. K. and Bell, P. M. and Shaner, J. W. and Steinberg, D. J.}, year={1978}, month=jun, pages={3276–3283} }