Abstract
Acute myocardial ischemia is a state of trauma of the heart muscle caused by occlusion of oxygenated blood supply. It is accompanied by an increase in potassium and hydrogen ion concentrations in the heart muscles. A flexible substrate based ion-sensitive field effect transistor (ISFET) has been designed to measure the concentration of potassium and hydrogen ions with high specificity. Double exponential smoothing technique was used to calculate background noise and explain the dependence of drain current on reference voltage and ion concentration in saturation mode of the ISFET.
References
22
Referenced
44
10.1067/mem.2001.114903
/ Ann. Emerg. Med. (2001)10.1161/01.CIR.91.7.2058
/ Circulation (1995)10.1016/S0003-2697(02)00220-8
/ Anal. Biochem. (2002)10.1016/S0003-2670(00)85001-1
/ Anal. Chim. Acta (1987)10.1063/1.2408659
/ Appl. Phys. Lett. (2006)10.1021/ja054347j
/ J. Am. Chem. Soc. (2006)10.1109/JSEN.2005.859252
/ IEEE Sens. J. (2005)10.1016/S0003-2670(01)01195-3
/ Anal. Chim. Acta (2001)10.1016/S0039-9140(00)00408-2
/ Talanta (2000)10.1016/j.bios.2007.01.019
/ Biosens. Bioelectron. (2007)10.1002/elan.200603609
/ Electroanalysis (2006)10.1002/elan.200403070
/ Electroanalysis (2004)10.1063/1.2747670
/ Appl. Phys. Lett. (2007)10.1063/1.1801673
/ Appl. Phys. Lett. (2004)10.1126/science.290.5499.2123
/ Science (2000){'year': '2003', 'key': '2023073122183180000_c16', 'first-page': '1172'}
(2003)10.1049/ip-cds:20045076
/ IEE Proc.: Circuits Devices Syst. (2005)10.1002/adma.19960080803
/ Adv. Mater. (Weinheim, Ger.) (1996)10.3141/1644-14
/ Transp. Res. Rec. (1998){'key': '2023073122183180000_c20', 'first-page': '652815', 'volume': '6528', 'year': '2007', 'journal-title': 'SPE Prod. Facil.'}
/ SPE Prod. Facil. (2007){'key': '2023073122183180000_c21'}
{'key': '2023073122183180000_c22', 'first-page': '280', 'volume-title': 'The Essential Physics of Medical Imaging', 'year': '2008', 'edition': '2nd ed.'}
/ The Essential Physics of Medical Imaging (2008)
Dates
Type | When |
---|---|
Created | 17 years, 2 months ago (June 12, 2008, 6:44 p.m.) |
Deposited | 2 years, 1 month ago (July 31, 2023, 6:18 p.m.) |
Indexed | 1 month ago (July 30, 2025, 6:51 a.m.) |
Issued | 17 years, 2 months ago (June 9, 2008) |
Published | 17 years, 2 months ago (June 9, 2008) |
Published Online | 17 years, 2 months ago (June 12, 2008) |
Published Print | 17 years, 2 months ago (June 9, 2008) |
@article{Ji_2008, title={In vitro evaluation of flexible pH and potassium ion-sensitive organic field effect transistor sensors}, volume={92}, ISSN={1077-3118}, url={http://dx.doi.org/10.1063/1.2936296}, DOI={10.1063/1.2936296}, number={23}, journal={Applied Physics Letters}, publisher={AIP Publishing}, author={Ji, Taeksoo and Rai, Pratyush and Jung, Soyoun and Varadan, Vijay K.}, year={2008}, month=jun }