Crossref journal-article
AIP Publishing
Journal of Applied Physics (317)
Abstract

After considering the various factors that limit the performance of the Kerr technique in the observation of magnetic domains, it is concluded that the ellipticity caused by metallic reflection is of major importance. A detailed calculation of this effect is carried out, including the case of normal incidence. It is theoretically found that, for microscopic observation of magnetic domains using the longitudinal Kerr effect, the contrast is practically independent of the angle of incidence, and that there is an upper limit to the resolution obtainable, which is a function of the minimum contrast needed for observation. This resolution is usually of the order of a few microns. A detailed description of a Kerr instrument designed for microscopic observations is included.

Bibliography

Treves, D. (1961). Limitations of the Magneto-Optic Kerr Technique in the Study of Microscopic Magnetic Domain Structures. Journal of Applied Physics, 32(3), 358–364.

Authors 1
  1. D. Treves (first)
References 18 Referenced 32
  1. 10.1063/1.1735535 / J. Appl. Phys. (1960)
  2. 10.1103/PhysRev.94.52 / Phys. Rev. (1954)
  3. {'key': '2024020119184811600_r3'}
  4. 10.1063/1.1735136 / J. Appl. Phys. (1959)
  5. {'key': '2024020119184811600_r5', 'first-page': '286', 'volume': '19', 'year': '1957–58', 'journal-title': 'Philips Tech. Rev.'} / Philips Tech. Rev. (1957–58)
  6. 10.1103/PhysRev.82.119 / Phys. Rev. (1951)
  7. {'key': '2024020119184811600_r7'}
  8. {'key': '2024020119184811600_r8'}
  9. {'key': '2024020119184811600_r9'}
  10. {'key': '2024020119184811600_r10'}
  11. {'key': '2024020119184811600_r11'}
  12. {'key': '2024020119184811600_r12'}
  13. {'key': '2024020119184811600_r13'}
  14. {'key': '2024020119184811600_r14'}
  15. {'key': '2024020119184811600_r15'}
  16. {'key': '2024020119184811600_r16'}
  17. {'key': '2024020119184811600_r17'}
  18. {'key': '2024020119184811600_r18'}
Dates
Type When
Created 20 years, 4 months ago (April 22, 2005, 12:28 p.m.)
Deposited 1 year, 6 months ago (Feb. 1, 2024, 2:43 p.m.)
Indexed 1 year, 6 months ago (Feb. 2, 2024, 8:40 p.m.)
Issued 64 years, 5 months ago (March 1, 1961)
Published 64 years, 5 months ago (March 1, 1961)
Published Print 64 years, 5 months ago (March 1, 1961)
Funders 0

None

@article{Treves_1961, title={Limitations of the Magneto-Optic Kerr Technique in the Study of Microscopic Magnetic Domain Structures}, volume={32}, ISSN={1089-7550}, url={http://dx.doi.org/10.1063/1.1736011}, DOI={10.1063/1.1736011}, number={3}, journal={Journal of Applied Physics}, publisher={AIP Publishing}, author={Treves, D.}, year={1961}, month=mar, pages={358–364} }