An electron absorption spectrometer with an improved velocity analyzer using the principle of individually designed stages for deceleration, dispersion, and reacceleration is described. The instrument is usable over an energy range of 1 to 50 kev and can obtain angular distribution data over a range of ±0.1 radian. The angular resolution is better than 10−3 radian. The demonstrated energy resolution at 20 kev is 0.6 ev. This resolution appears to be limited by the primary beam energy spread which is characteristic of a beam produced by a telefocus gun with a tungsten cathode.

Bibliography

Marton, L., & Simpson, J. A. (1958). Electron Absorption Spectrometer Using an Improved Velocity Analyzer. Review of Scientific Instruments, 29(7), 567–570.

Authors 2
  1. L. Marton (first)
  2. J. Arol Simpson (additional)
References 18 Referenced 28
  1. {'key': '2023063019310505100_r1'}
  2. {'key': '2023063019310505100_r2', 'first-page': '499', 'volume': '5', 'year': '1949', 'journal-title': 'Optik'} / Optik (1949)
  3. {'key': '2023063019310505100_r2a', 'first-page': '244', 'volume': 'B64', 'year': '1951', 'journal-title': 'Proc. Phys. Soc. (London)'} / Proc. Phys. Soc. (London) (1951)
  4. 10.1063/1.1715327 / Rev. Sci. Instr. (1955)
  5. 10.1063/1.1771275 / Rev. Sci. Instr. (1955)
  6. 10.1063/1.1715326 / Rev. Sci. Instr. (1955)
  7. 10.1007/BF01375256 / Z. Physik (1954)
  8. {'key': '2023063019310505100_r3a', 'first-page': '226', 'volume': '135', 'year': '1954', 'journal-title': 'Z. Physik'} / Z. Physik (1954)
  9. 10.1103/PhysRev.95.345 / Phys. Rev. (1954)
  10. 10.1103/PhysRev.98.889 / Phys. Rev. (1955)
  11. 10.1103/PhysRev.107.1553 / Phys. Rev. (1957)
  12. {'key': '2023063019310505100_r4'}
  13. {'key': '2023063019310505100_r5'}
  14. {'key': '2023063019310505100_r6', 'first-page': '3719', 'volume': '38', 'year': '1953', 'journal-title': 'Natl. Bur. Standards (U.S.) Tech. News Bull.'} / Natl. Bur. Standards (U.S.) Tech. News Bull. (1953)
  15. {'key': '2023063019310505100_r7', 'first-page': '337', 'volume': '4', 'year': '1952', 'journal-title': 'Arkiv Fysik'} / Arkiv Fysik (1952)
  16. 10.1063/1.1746254 / Rev. Sci. Instr. (1952)
  17. {'key': '2023063019310505100_r9', 'first-page': '469', 'volume': '5', 'year': '1949', 'journal-title': 'Optik'} / Optik (1949)
  18. 10.1063/1.1751548 / Rev. Sci. Instr. (1939)
Dates
Type When
Created 20 years, 6 months ago (Feb. 12, 2005, 4:31 p.m.)
Deposited 2 years, 1 month ago (June 30, 2023, 3:31 p.m.)
Indexed 1 year, 6 months ago (Feb. 11, 2024, 2:56 a.m.)
Issued 67 years, 1 month ago (July 1, 1958)
Published 67 years, 1 month ago (July 1, 1958)
Published Online 20 years, 7 months ago (Dec. 29, 2004)
Published Print 67 years, 1 month ago (July 1, 1958)
Funders 0

None

@article{Marton_1958, title={Electron Absorption Spectrometer Using an Improved Velocity Analyzer}, volume={29}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1716260}, DOI={10.1063/1.1716260}, number={7}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Marton, L. and Simpson, J. Arol}, year={1958}, month=jul, pages={567–570} }