Abstract

A point focusing x-ray monochromator which uses Bragg reflection from a single lamina of quartz bent in such a way that its atomic planes are given two principal radii of curvature has been constructed for use in low-angle diffraction studies. It was found that the crystal reflects 2.78% of the incident Cu Kα1 radiation into a converging beam one meter long, with a resolution of better than half a millimeter except for a very faint halo. The instrument has been used to obtain diffraction patterns from normal and sickle-cell human hemoglobin and also from southern bean mosaic virus. The speed of the present instrument is roughly two hundred times that of an equivalent pinhole collimating system. A similar but still faster instrument is being constructed.

Bibliography

Berreman, D. W. (1955). Single Quartz Crystal Point Focusing X-Ray Monochromator. Review of Scientific Instruments, 26(11), 1048–1052.

Authors 1
  1. Dwight W. Berreman (first)
References 15 Referenced 19
  1. {'key': '2024020711384459300_r1', 'first-page': '1219', 'volume': '25', 'year': '1954', 'journal-title': 'Rev. Sci. Instr.'} / Rev. Sci. Instr. (1954)
  2. {'key': '2024020711384459300_r2'}
  3. {'key': '2024020711384459300_r3', 'first-page': '716', 'volume': '235', 'year': '1952', 'journal-title': 'Compt. Rend.'} / Compt. Rend. (1952)
  4. {'key': '2024020711384459300_r4'}
  5. {'key': '2024020711384459300_r5', 'first-page': '325', 'volume': '27', 'year': '1914', 'journal-title': 'Phil. Mag.'} / Phil. Mag. (1914)
  6. {'key': '2024020711384459300_r6', 'first-page': '519', 'volume': '54', 'year': '1917', 'journal-title': 'Ann. Phys.'} / Ann. Phys. (1917)
  7. {'key': '2024020711384459300_r7'}
  8. {'key': '2024020711384459300_r8'}
  9. 10.1364/JOSA.16.000375 / J. Opt. Soc. Am. (1928)
  10. 10.1063/1.1751523 / Rev. Sci. Instr. (1939)
  11. 10.1016/0006-3002(50)90043-6 / Biochim. et Biophys. Acta (1950)
  12. {'key': '2024020711384459300_r12', 'first-page': '567', 'volume': '7', 'year': '1952', 'journal-title': 'Rev. d’Hematologie'} / Rev. d’Hematologie (1952)
  13. {'key': '2024020711384459300_r13', 'first-page': '33', 'volume': '222', 'year': '1954', 'journal-title': 'Proc. Roy. Soc. (London)'} / Proc. Roy. Soc. (London) (1954)
  14. 10.1016/0006-3002(53)90180-2 / Biochim. et Biophys. Acta (1953)
  15. {'key': '2024020711384459300_r15'}
Dates
Type When
Created 20 years, 6 months ago (Feb. 12, 2005, 1:06 p.m.)
Deposited 1 year, 6 months ago (Feb. 7, 2024, 1:15 p.m.)
Indexed 1 year, 6 months ago (Feb. 10, 2024, 9:25 p.m.)
Issued 69 years, 9 months ago (Nov. 1, 1955)
Published 69 years, 9 months ago (Nov. 1, 1955)
Published Print 69 years, 9 months ago (Nov. 1, 1955)
Funders 0

None

@article{Berreman_1955, title={Single Quartz Crystal Point Focusing X-Ray Monochromator}, volume={26}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1715183}, DOI={10.1063/1.1715183}, number={11}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Berreman, Dwight W.}, year={1955}, month=nov, pages={1048–1052} }