Abstract
When a very good planar Ge(Li) detector (3.8 cm2 × 9 mm, ∼77°K, ∼1 kV/cm) was irradiated by a slit-collimated 137Cs γ-ray beam (slit width, ∼0.25 mm) incident parallel to the n+ -i and the i-p junctions, a large and abrupt increase in the relative counting rate of slow rising pulses was observed near the two junctions. The slow pulses had much longer rise times (> 0.5 μsec) than those of the normal fast rising pulses whose rise times were determined by the transit times of the carriers.
References
8
Referenced
7
{'key': '2024020506375622100_r1', 'first-page': '86', 'volume': '13', 'year': '1964', 'journal-title': 'Phys. Rev. Letters'}
/ Phys. Rev. Letters (1964)10.1016/0029-554X(67)90329-1
/ Nucl. Instr. and Meth. (1967){'key': '2024020506375622100_r3'}
10.1016/0029-554X(67)90263-7
/ Nucl. Instr. and Meth. (1967){'key': '2024020506375622100_r4'}
{'key': '2024020506375622100_r5'}
{'key': '2024020506375622100_r6'}
{'key': '2024020506375622100_r7'}
Dates
Type | When |
---|---|
Created | 21 years, 7 months ago (Jan. 30, 2004, 3:03 p.m.) |
Deposited | 1 year, 6 months ago (Feb. 5, 2024, 1:38 a.m.) |
Indexed | 1 year, 6 months ago (Feb. 5, 2024, 2:10 a.m.) |
Issued | 57 years, 4 months ago (April 15, 1968) |
Published | 57 years, 4 months ago (April 15, 1968) |
Published Print | 57 years, 4 months ago (April 15, 1968) |
@article{Sakai_1968, title={SLOW PULSES FROM A PLANAR Ge(Li) DETECTOR}, volume={12}, ISSN={1077-3118}, url={http://dx.doi.org/10.1063/1.1651987}, DOI={10.1063/1.1651987}, number={8}, journal={Applied Physics Letters}, publisher={AIP Publishing}, author={Sakai, Eiji}, year={1968}, month=apr, pages={269–271} }