Crossref journal-article
AIP Publishing
Review of Scientific Instruments (317)
Abstract

The response function of a Si(Li) detector has been measured in the photon energy range 0.9–5 keV using monochromatized synchrotron radiation at a double crystal monochromator. The response is described by a hypermet function and the spectral dependence of its parameters is presented. The quantum detection efficiency of the detector is determined from measurements in the undispersed synchrotron radiation of the electron storage ring BESSY, which is a primary radiometric standard.

Bibliography

Krumrey, M., Tegeler, E., & Ulm, G. (1989). Complete characterization of a Si(Li) detector in the photon energy range 0.9–5 keV. Review of Scientific Instruments, 60(7), 2287–2290.

Authors 3
  1. M. Krumrey (first)
  2. E. Tegeler (additional)
  3. G. Ulm (additional)
References 17 Referenced 38
  1. {'key': '2024020701232942200_r1', 'first-page': '486', 'volume': '733', 'year': '1986', 'journal-title': 'SPIE'} / SPIE (1986)
  2. 10.1002/xrs.1300160603 / X-ray Spectrom. (1987)
  3. 10.1016/0168-9002(86)91024-7 / Nucl. Instrum. Methods A (1986)
  4. 10.1088/0026-1394/22/2/002 / Metrologia (1986)
  5. {'key': '2024020701232942200_r5', 'first-page': '242', 'volume': '733', 'year': '1987', 'journal-title': 'SPIE'} / SPIE (1987)
  6. 10.1016/0168-583X(85)90780-3 / Nucl. Instrum. Methods B (1985)
  7. 10.1016/0168-583X(87)90513-1 / Nucl. Instrum. Methods B (1987)
  8. {'key': '2024020701232942200_r8'}
  9. 10.1016/0168-583X(87)90120-0 / Nucl. Instrum. Methods B (1987)
  10. {'key': '2024020701232942200_r10'}
  11. 10.1002/xrs.1300110412 / X-ray Spectrom. (1982)
  12. 10.1002/xrs.1300160503 / X-ray Spectrom. (1987)
  13. 10.1016/0168-583X(84)90484-1 / Nucl. Instrum. Methods B (1984)
  14. {'key': '2024020701232942200_r14', 'first-page': '142', 'volume': '75', 'year': '1987', 'journal-title': 'Optik'} / Optik (1987)
  15. 10.1016/S0092-640X(73)80015-4 / At. Data Nucl. Data Tables (1973)
  16. 10.1016/0092-640X(82)90002-X / At. Data Nucl. Data Tables (1982)
  17. {'key': '2024020701232942200_r17'}
Dates
Type When
Created 23 years, 1 month ago (July 26, 2002, 9:22 a.m.)
Deposited 1 year, 6 months ago (Feb. 6, 2024, 10:27 p.m.)
Indexed 1 year, 6 months ago (Feb. 11, 2024, 3:51 a.m.)
Issued 36 years, 2 months ago (July 1, 1989)
Published 36 years, 2 months ago (July 1, 1989)
Published Print 36 years, 2 months ago (July 1, 1989)
Funders 0

None

@article{Krumrey_1989, title={Complete characterization of a Si(Li) detector in the photon energy range 0.9–5 keV}, volume={60}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1140795}, DOI={10.1063/1.1140795}, number={7}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Krumrey, M. and Tegeler, E. and Ulm, G.}, year={1989}, month=jul, pages={2287–2290} }