Abstract
In the summer of 1988, the National Synchrotron Light Source installed a 35 period soft-x-ray undulator. We are using this device as a radiation source for a beamline designed for soft-x-ray imaging experiments that require high brightness for practical operation. We present the design philosophy and implementation of this beamline. Preliminary characterization of the beamline and undulator indicate that the central intensity of the undulator is within a factor of 2 of design. We have measured an intensity of more than 1015 photons/s/0.1% BW/mrad2 at 36 Å. The monochromator has achieved its design resolving power of 2000.
Bibliography
Buckley, C., Rarback, H., Alforque, R., Shu, D., Ade, H., Hellman, S., Iskander, N., Kirz, J., Lindaas, S., Mcnulty, I., Oversluizen, M., Tang, E., Attwood, D., DiGennaro, R., Howells, M., Jacobsen, C., Vladimirsky, Y., Rothman, S., Kern, D., & Sayre, D. (1989). Soft-x-ray imaging with the 35 period undulator at the NSLS. Review of Scientific Instruments, 60(7), 2444â2447.
Authors
20
- C. Buckley (first)
- H. Rarback (additional)
- R. Alforque (additional)
- D. Shu (additional)
- H. Ade (additional)
- S. Hellman (additional)
- N. Iskander (additional)
- J. Kirz (additional)
- S. Lindaas (additional)
- I. Mcnulty (additional)
- M. Oversluizen (additional)
- E. Tang (additional)
- D. Attwood (additional)
- R. DiGennaro (additional)
- M. Howells (additional)
- C. Jacobsen (additional)
- Y. Vladimirsky (additional)
- S. Rothman (additional)
- D. Kern (additional)
- D. Sayre (additional)
References
18
Referenced
16
{'key': '2024020610274279800_r1'}
10.1016/0168-9002(88)90437-8
/ Nucl. Instrum. Methods A (1988)10.1016/0168-9002(88)90376-2
/ Nucl. Instrum. Methods A (1988)10.1063/1.1139965
/ Rev. Sci. Instrum. (1988){'key': '2024020610274279800_r5', 'first-page': '311', 'volume': '6', 'year': '1988', 'journal-title': 'J. Vac. Sci. Technol. B.'}
/ J. Vac. Sci. Technol. B. (1988){'key': '2024020610274279800_r6', 'volume': '266', 'year': '1988', 'journal-title': 'Nucl. Instrum. Methods A'}
/ Nucl. Instrum. Methods A (1988){'key': '2024020610274279800_r7'}
10.1126/science.3659925
/ Science (1987){'key': '2024020610274279800_r9'}
{'key': '2024020610274279800_r10'}
{'key': '2024020610274279800_r11'}
{'key': '2024020610274279800_r12'}
{'key': '2024020610274279800_r13'}
{'key': '2024020610274279800_r14', 'first-page': '3078', 'volume': 'NS-30', 'year': '1983', 'journal-title': 'IEEE Trans. Nucl. Sci.'}
/ IEEE Trans. Nucl. Sci. (1983)10.1016/0168-9002(88)90366-X
/ Nucl. Instrum. Methods A (1988)10.1016/0168-9002(86)90115-4
/ Nucl. Instrum. Methods A (1986)10.1016/0168-9002(86)90115-4
/ Nucl. Instrum. Methods A (1986){'key': '2024020610274279800_r18'}
Dates
Type | When |
---|---|
Created | 23 years, 1 month ago (July 26, 2002, 9:19 a.m.) |
Deposited | 1 year, 6 months ago (Feb. 6, 2024, 5:49 a.m.) |
Indexed | 1 year, 6 months ago (Feb. 7, 2024, 4:57 a.m.) |
Issued | 36 years, 1 month ago (July 1, 1989) |
Published | 36 years, 1 month ago (July 1, 1989) |
Published Print | 36 years, 1 month ago (July 1, 1989) |
@article{Buckley_1989, title={Soft-x-ray imaging with the 35 period undulator at the NSLS}, volume={60}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1140694}, DOI={10.1063/1.1140694}, number={7}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Buckley, C. and Rarback, H. and Alforque, R. and Shu, D. and Ade, H. and Hellman, S. and Iskander, N. and Kirz, J. and Lindaas, S. and Mcnulty, I. and Oversluizen, M. and Tang, E. and Attwood, D. and DiGennaro, R. and Howells, M. and Jacobsen, C. and Vladimirsky, Y. and Rothman, S. and Kern, D. and Sayre, D.}, year={1989}, month=jul, pages={2444–2447} }