Crossref journal-article
AIP Publishing
Review of Scientific Instruments (317)
Abstract

A tungsten ribbon and a grounded sample form two electrodes of a vibrating capacitor connected to a sensitive radio frequency capacitance bridge and to a source of dc and ac bias. The ac bias frequency is tuned to the fundamental resonance of the ribbon (f?2.5 kHz, Q≳500) and the work function difference between the ribbon and the sample is determined from the dc bias for which the ribbon capacitance variation at the ac driving frequency vanishes. Work function differences at different positions on a flat sample can be measured to millivolt precision. An example of the change in work function of evaporated Ag–Au alloys with oxygen exposure is given.

Bibliography

Fain, S. C., Corbin, L. V., & McDavid, J. M. (1976). Electrostatically driven apparatus for measuring work function differences. Review of Scientific Instruments, 47(3), 345–347.

Authors 3
  1. S. C. Fain (first)
  2. L. V. Corbin (additional)
  3. J. M. McDavid (additional)
References 16 Referenced 12
  1. 10.1080/14786449808621172 / Philos. Mag. (1898)
  2. 10.1088/0022-3735/3/7/201 / J. Phys. E (1970)
  3. {'key': '2024020615362668100_r3'}
  4. 10.1016/S0360-0564(08)60417-4 / Adv. Catal. Relat. Subj. (1959)
  5. 10.1063/1.1748947 / Rev. Sci. Instrum. (1932)
  6. 10.1088/0022-3735/1/4/314 / J. Phys. E (1968)
  7. {'key': '2024020615362668100_r7'}
  8. 10.1088/0950-7671/42/12/311 / J. Sci. Instrum. (1965)
  9. {'key': '2024020615362668100_r9'}
  10. 10.1103/PhysRevB.9.5099 / Phys. Rev. B (1974)
  11. {'key': '2024020615362668100_r11'}
  12. {'key': '2024020615362668100_r12', 'first-page': '1061', 'volume': '8', 'year': '1973', 'journal-title': 'Phys. Rev. B'} / Phys. Rev. B (1973)
  13. {'key': '2024020615362668100_r13'}
  14. {'key': '2024020615362668100_r14'}
  15. {'key': '2024020615362668100_r15'}
  16. 10.1063/1.1686287 / Rev. Sci. Instrum. (1973)
Dates
Type When
Created 22 years, 5 months ago (March 10, 2003, 12:42 p.m.)
Deposited 1 year, 6 months ago (Feb. 6, 2024, 1:23 p.m.)
Indexed 5 months ago (March 24, 2025, 2:38 a.m.)
Issued 49 years, 5 months ago (March 1, 1976)
Published 49 years, 5 months ago (March 1, 1976)
Published Print 49 years, 5 months ago (March 1, 1976)
Funders 0

None

@article{Fain_1976, title={Electrostatically driven apparatus for measuring work function differences}, volume={47}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1134620}, DOI={10.1063/1.1134620}, number={3}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Fain, S. C. and Corbin, L. V. and McDavid, J. M.}, year={1976}, month=mar, pages={345–347} }