Abstract
An apparatus is described which allows studies to pressures of 100 kilobar and to temperatures of 0.03 K. A low temperature hydraulic press is incorporated with a dilution refrigerator to permit the continuous variation in pressure while at low temperature; thus, the entire pressure study of a material can be accomplished in one low temperature run. The sample is sensed magnetically using a SQUID magnetometer to detect changes in its magnetic moment. Operation of the system is described for measurements of the transition temperature of aluminum as a function of temperature and pressure.
References
21
Referenced
66
10.1070/PU1965v008n02ABEH003037
/ Sov. Phys.-Usp. (1965)10.1080/00107516908204793
/ Contemp. Phys. (1969){'key': '2024021014441787900_r3'}
10.1007/BF00630915
/ J. Low Temp. Phys. (1972)10.1063/1.1683719
/ Rev. Sci. lnstrum. (1969){'key': '2024021014441787900_r6', 'first-page': '656', 'volume': '179', 'year': '1960', 'journal-title': 'Phys. Rev.'}
/ Phys. Rev. (1960){'key': '2024021014441787900_r7', 'first-page': '261', 'volume': '31', 'year': '1967', 'journal-title': 'Z. Angew. Phys.'}
/ Z. Angew. Phys. (1967)10.1063/1.1685594
/ Rev. Sci. Instrum. (1972)10.1063/1.1686499
/ Rev. Sci. Instrum. (1974)10.1063/1.1686569
/ Rev. Sci. Instrum. (1974)10.1016/0022-3697(69)90310-2
/ J. Phys. Chem. Solids (1969)10.1063/1.1721072
/ Rev. Sci. Instrum. (1967)10.1007/BF01375164
/ Z. Phys. (1963){'key': '2024021014441787900_r14'}
10.1063/1.1719911
/ Rev. Sci. Instrum. (1965)10.1063/1.1683156
/ Rev. Sci. Instrum. (1968)10.1007/BF00644085
/ J. Low Temp. Phys. (1972)10.1063/1.1720525
/ Rev. Sci. Instrum. (1967){'key': '2024021014441787900_r19'}
{'key': '2024021014441787900_r20'}
10.1103/PhysRevLett.35.104
/ Phys. Rev. Lett. (1975)
Dates
Type | When |
---|---|
Created | 22 years, 5 months ago (March 10, 2003, 12:42 p.m.) |
Deposited | 1 year, 6 months ago (Feb. 10, 2024, 10:57 a.m.) |
Indexed | 1 month ago (July 25, 2025, 6:47 a.m.) |
Issued | 49 years, 7 months ago (Jan. 1, 1976) |
Published | 49 years, 7 months ago (Jan. 1, 1976) |
Published Print | 49 years, 7 months ago (Jan. 1, 1976) |
@article{Webb_1976, title={Cryostat for generating pressures to 100 kilobar and temperatures to 0.03 K}, volume={47}, ISSN={1089-7623}, url={http://dx.doi.org/10.1063/1.1134491}, DOI={10.1063/1.1134491}, number={1}, journal={Review of Scientific Instruments}, publisher={AIP Publishing}, author={Webb, A. W. and Gubser, D. U. and Towle, L. C.}, year={1976}, month=jan, pages={59–62} }