Crossref journal-article
Elsevier BV
The Journal of Hand Surgery (78)
Bibliography

Peckham, P. H., Kilgore, K. L., Keith, M. W., Bryden, A. M., Bhadra, N., & Montague, F. W. (2002). An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller. The Journal of Hand Surgery, 27(2), 265–276.

Authors 6
  1. P.Hunter Peckham (first)
  2. Kevin L. Kilgore (additional)
  3. Michael W. Keith (additional)
  4. Anne M. Bryden (additional)
  5. Niloy Bhadra (additional)
  6. Fred W. Montague (additional)
References 34 Referenced 87
  1. 10.2106/00004623-197557020-00012 / J Bone Joint Surg / Surgical treatment for absent single-hand grip and elbow extension in quadriplegia by Moberg (1975)
  2. 10.1016/S0749-0712(21)01223-3 / Hand Clin / New concepts on treatment of the upper limb in the tetraplegic: surgical restoration and functional neuromuscular stimulation by Freehafer (1988)
  3. {'key': '10.1053/jhsu.2002.30919_bib3', 'first-page': '439', 'article-title': 'Functional restoration of the upper extremity in tetraplegia', 'author': 'Hentz', 'year': '1995'} / Functional restoration of the upper extremity in tetraplegia by Hentz (1995)
  4. 10.1016/S0363-5023(96)80160-2 / J Hand Surg / Tendon transfers and functional electrical stimulation for restoration of hand function in spinal cord injury by Keith (1996)
  5. 10.1053/apmr.2001.25910 / Arch Phys Med Rehabil / Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study by Peckham (2001)
  6. 10.2106/00004623-199704000-00008 / J Bone Joint Surg / An implanted upper-extremity neuroprosthesis: follow-up of five patients by Kilgore (1997)
  7. 10.1016/0363-5023(94)90008-6 / J Hand Surg / Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis by Wuolle (1994)
  8. 10.1080/01952307.1994.11735912 / J Am Paraplegia Soc / Functional neuromuscular stimulation: outcomes in young people with tetraplegia by Mulcahey (1994)
  9. 10.1038/sc.1996.3 / Paraplegia / Quantitative comparison of grasp and release abilities with and without functional neuromuscular stimulation in adolescents with tetraplegia by Smith (1996)
  10. 10.1016/S0003-9993(99)90123-5 / Arch Phys Med Rehabil / Satisfaction with and usage of a hand neuroprosthesis by Wuolle (1999)
  11. 10.1080/10400435.2000.10132010 / Assistive Technol / Reduction of costs of disability using neuroprosthesis by Creasey (2000)
  12. 10.1109/86.750547 / IEEE Trans Rehabil Eng / The function of the finger intrinsic muscles in response to electrical stimulation by Lauer (1999)
  13. 10.1109/86.313149 / IEEE Trans Rehabil Eng / A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system by Memberg (1994)
  14. 10.1109/10.58598 / IEEE Trans Biomed Eng / Evaluation of shoulder movement as a command control source by Johnson (1990)
  15. 10.1109/86.681187 / IEEE Trans Rehabil Eng / A comparison between control methods for implanted FES hand-grasp systems by Hart (1998)
  16. 10.1109/86.788471 / IEEE Trans Rehabil Eng / An implantable transducer for two-degree of freedom joint angle sensing by Johnson (1999)
  17. 10.1109/86.681185 / IEEE Trans Rehabil Eng / Functional neuromuscular stimulation for combined control of elbow extension and hand grasp in C5 and C6 quadriplegics by Grill (1998)
  18. 10.1109/86.662614 / IEEE Trans Rehabil Eng / An elbow extension neuroprosthesis for individuals with tetraplegia by Crago (1998)
  19. 10.1016/S0003-9993(00)90226-0 / Arch Phys Med Rehabil / Electrically stimulated elbow extension in persons with C5/C6 tetraplegia: a functional and physiological evaluation by Bryden (2000)
  20. 10.1016/0021-9290(95)00076-3 / J Biomech / Restoration of pronosupination control by FNS in tetraplegia: experimental and biomechanical evaluation of feasibility by Lemay (1996)
  21. 10.1109/10.664202 / IEEE Trans Biomed Eng / An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle by Smith (1998)
  22. 10.1109/10.376158 / IEEE Trans Biomed Eng / Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulator by Tang (1995)
  23. 10.1109/TBME.1987.325979 / IEEE Trans Biomed Eng / An externally powered, multichannel implantable stimulator for versatile control of paralyzed muscle by Smith (1987)
  24. 10.1109/86.331566 / IEEE Trans Rehabil Eng / Instrumented assessment of FNS hand control during specific manipulation tasks by Burelbach (1994)
  25. 10.1109/10.83572 / IEEE Trans Biomed Eng / In-line lead connector for use with implanted neuroprosthesis by Letechipia (1991)
  26. {'key': '10.1053/jhsu.2002.30919_bib26', 'series-title': 'Standards for neurological classification of spinal injury patients', 'author': 'American Spinal Injury Association', 'year': '1992'} / Standards for neurological classification of spinal injury patients by American Spinal Injury Association (1992)
  27. 10.1016/S0363-5023(79)80083-0 / J Hand Surg / International conference on surgical rehabilitation of the upper extremity in tetraplegia by McDowell (1979)
  28. 10.1016/S0363-5023(89)80017-6 / J Hand Surg / Implantable functional neuromuscular stimulation in the tetraplegic hand by Keith (1989)
  29. 10.1007/BF02441809 / Med Biol Eng Comput / Grasp synthesis for upper-extremity FNS: part 1 automated method for synthesizing the stimulus map by Kilgore (1993)
  30. 10.1109/86.593301 / IEEE Trans Rehabil Eng / Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes by Akers (1997)
  31. 10.1109/10.32109 / IEEE Trans Biomed Eng / Synthesis of hand grasp using functional neuromuscular stimulation by Kilgore (1989)
  32. 10.1007/BF02345019 / Med Biol Eng Comput / Structured sleeve for repair of implantable in-line connectors by Strojnik (2000)
  33. {'key': '10.1053/jhsu.2002.30919_bib33', 'series-title': 'Implementation of an implantable joint angle transducer', 'author': 'Bhadra', 'year': '2000'} / Implementation of an implantable joint angle transducer by Bhadra (2000)
  34. 10.1046/j.1525-1594.1999.06358.x / Artif Organs / A custom designed chip to control an implantable stimulator and telemetry system for control of paralyzed muscles by Pourmehdi (1999)
Dates
Type When
Created 23 years ago (Aug. 24, 2002, 11:46 p.m.)
Deposited 4 years, 3 months ago (May 16, 2021, 1:25 a.m.)
Indexed 2 months, 2 weeks ago (June 14, 2025, 11:10 a.m.)
Issued 23 years, 6 months ago (March 1, 2002)
Published 23 years, 6 months ago (March 1, 2002)
Published Print 23 years, 6 months ago (March 1, 2002)
Funders 0

None

@article{Peckham_2002, title={An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller}, volume={27}, ISSN={0363-5023}, url={http://dx.doi.org/10.1053/jhsu.2002.30919}, DOI={10.1053/jhsu.2002.30919}, number={2}, journal={The Journal of Hand Surgery}, publisher={Elsevier BV}, author={Peckham, P.Hunter and Kilgore, Kevin L. and Keith, Michael W. and Bryden, Anne M. and Bhadra, Niloy and Montague, Fred W.}, year={2002}, month=mar, pages={265–276} }