Johnson, J., & Dawson-Hughes, B. (1991). Precision and stability of dual-energy X-ray absorptiometry measurements. Calcified Tissue International, 49(3), 174–178.

Authors 2
  1. Jennifer Johnson (first)
  2. Bess Dawson-Hughes (additional)
References 14 Referenced 175
  1. Mazess RB, Barden HS (1988) Measurement of bone by dualphoton absorptiometry (DPA) and dual-energy X-ray absorptiometry (DEXA). Ann Chir Gynaecol 77:197–203 / Ann Chir Gynaecol by RB Mazess (1988)
  2. Pacifici R, Rupich R, Vered I, Fischer KC, Griffin M Susman N, Avioli LV (1988) Dual energy radiography (DER): a preliminary comparative study. Calcif Tissue Int 43:189–191 (10.1007/BF02571319) / Calcif Tissue Int by R Pacifici (1988)
  3. Mazess RB, Collick B, Trempe J, Barden H, Hanson J (1989) Performance evaluation of a dual-energy X-ray bone densitometer. Calcif Tissue Int 44:228–232 (10.1007/BF02556569) / Calcif Tissue Int by RB Mazess (1989)
  4. Cullum ID, Ell PJ, Ryder JP (1989) X-ray dual-photon absorptiometry: a new method for the measurement of bone density. Br J Radiol 62:587–592 (10.1259/0007-1285-62-739-587) / Br J Radiol by ID Cullum (1989)
  5. Slosman DO, Rizzoli R, Donath A, Bonjour J-Ph (1990) Precision of X-ray and Gd-153 bone densitometers at the levels of the spine (frontal and lateral views), femoral neck and shaft (abstract). Calcif Tissue Int 46 (supp 2):142 / Calcif Tissue Int by DO Slosman (1990)
  6. Nijs J, Geusens P, Dequeker J, Verstraeten A (1988) Reproducibility and intercorrelations of total bone mineral and dissected regional BMC measurements. In: Dequeker JV, Geusens P and Wahner HW (eds) Bone mineral measurements by photon absorptiometry: methodological problems. Leuven University Press, Leuven, Belgium, pp 451–453 / Bone mineral measurements by photon absorptiometry: methodological problems by J Nijs (1988)
  7. Dawson-Hughes B, Deehr MS, Berger PS, Dallal GE, Sadowski LJ (1989) Correction of the effects of source, source strength, and soft-tissue thickness on spine dual-photon absorptiometry measurements. Calcif Tissue Int 44:251–257 (10.1007/BF02553759) / Calcif Tissue Int by B Dawson-Hughes (1989)
  8. Nilas L, Hassager C, Christiansen C (1988) Long-term precision of dual photon absorptiometry in the lumbar spine in clinical settings. Bone Miner 3:305–315 (10.1002/jbmr.5650030309) / Bone Miner by L Nilas (1988)
  9. Lindsay R, Fey C, Haboubi A (1987) Dual photon absorptiometry measurements of bone mineral density increase with source life. Calcif Tissue Int 41:293–294 (10.1007/BF02555232) / Calcif Tissue Int by R Lindsay (1987)
  10. Ross PD, Wasnich RD, Vogel JM (1988) Precision error in dual-photon absorptiometry related to source age. Radiology 166:523–527 (10.1148/radiology.166.2.3336729) / Radiology by PD Ross (1988)
  11. Heymsfield SB, Wang J, Heshka S, Kehayias JJ, Pierson RN (1989) Dual-photon absorptiometry: comparison of bone mineral and soft tissue mass measurements in vivo with established methods. Am J Clin Nutr 49:1283–1289 (10.1093/ajcn/49.6.1283) / Am J Clin Nutr by SB Heymsfield (1989)
  12. Wahner HW, Dunn WL, Brown ML (1988) Comparison of dual-energy X-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine. Mayo Clin Proc 63:1075–1084 (10.1016/S0025-6196(12)65502-5) / Mayo Clin Proc by HW Wahner (1988)
  13. Kelly TL, Slovik DM, Schoenfeld DA, Neer RM (1988) Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab 67:839–844 (10.1210/jcem-67-4-839) / J Clin Endocrinol Metab by TL Kelly (1988)
  14. Strause L, Bracker M, Saltman P, Sartoris D, Kerr E (1989) A comparison of quantitative dual-energy radiographic absorptiometry and dual photon absorptiometry of the lumbar spine in postmenopausal women. Calcif Tissue Int 45:288–291 (10.1007/BF02556021) / Calcif Tissue Int by L Strause (1989)
Dates
Type When
Created 18 years, 6 months ago (Feb. 7, 2007, 11:47 a.m.)
Deposited 1 year, 6 months ago (Feb. 10, 2024, 3:34 p.m.)
Indexed 1 day, 14 hours ago (Aug. 29, 2025, 5:52 a.m.)
Issued 34 years, 3 months ago (May 1, 1991)
Published 34 years, 3 months ago (May 1, 1991)
Published Print 34 years, 3 months ago (May 1, 1991)
Funders 0

None

@article{Johnson_1991, title={Precision and stability of dual-energy X-ray absorptiometry measurements}, volume={49}, ISSN={1432-0827}, url={http://dx.doi.org/10.1007/bf02556113}, DOI={10.1007/bf02556113}, number={3}, journal={Calcified Tissue International}, publisher={Springer Science and Business Media LLC}, author={Johnson, Jennifer and Dawson-Hughes, Bess}, year={1991}, month=may, pages={174–178} }