Crossref journal-article
Wiley
Magnetic Resonance in Medicine (311)
Abstract

AbstractThis work investigates the general problem of phase unwrapping for arbitrary N‐dimensional phase maps. A cost function‐based approach is outlined that leads to an integer programming problem. To solve this problem, a best‐pair‐first region merging approach is adopted as the optimization method. The algorithm was implemented and tested with 3D MRI medical data for venogram studies, as well as for fMRI applications in EPI unwarping and rapid, automated shimming. Magn Reson Med 49:193–197, 2003. © 2003 Wiley‐Liss, Inc.

Bibliography

Jenkinson, M. (2002). Fast, automated, N‐dimensional phase‐unwrapping algorithm. Magnetic Resonance in Medicine, 49(1), 193–197. Portico.

Authors 1
  1. Mark Jenkinson (first)
References 20 Referenced 623
  1. 10.1109/42.875186
  2. 10.1002/mrm.1910340111
  3. WeisskoffRM DavisTL.Correcting gross distotion on echo planar images. In: Proceedings of the 11th Annual Meeting of ISMRM Berlin Germany 1992. p4515.
  4. 10.1002/mrm.1910180211
  5. 10.1097/00004728-198609000-00001
  6. 10.1109/42.544507
  7. 10.1109/83.148608
  8. 10.1364/JOSAA.18.000338
  9. KrämerR LoffeldO.Phase unwrapping for SAR interferometry with Kalman filters. In: Proceedings of the EUSAR Conference Königswinter Germany1996. p165–169.
  10. WangY Debiao LiD HaackeM.A new phase unwrapping method for water and fat separation in inhomogeneous fields. In: Proceedings of the 3rd Annual Meeting of ISMRM Nice France 1995.
  11. 10.1002/1522-2594(200007)44:1<122::AID-MRM18>3.0.CO;2-C
  12. {'key': 'e_1_2_6_13_2', 'first-page': '529', 'article-title': 'Temporal phase unwrapping for CINE velocity imaging', 'volume': '5', 'author': 'Xiang QS', 'year': '1995', 'journal-title': 'Magn Reson Med'} / Magn Reson Med / Temporal phase unwrapping for CINE velocity imaging by Xiang QS (1995)
  13. 10.1364/JOSAA.17.000021
  14. SoberingGS ShiferawY van GelderenP MoonenCTW.Quantitative measurement of the phase error for a simple and rapid phase‐unwrapping algorithm. In: Proceedings of the 3rd Annual Meeting of ISMRM Nice France 1995.
  15. 10.1148/radiology.192.2.8029431
  16. 10.1109/42.876306
  17. 10.1109/83.382500
  18. 10.1118/1.596378
  19. 10.1002/mrm.1910240120
  20. 10.1006/nimg.2002.1092
Dates
Type When
Created 22 years, 8 months ago (Jan. 1, 2003, 4:01 p.m.)
Deposited 1 year, 10 months ago (Oct. 13, 2023, 6:14 p.m.)
Indexed 10 minutes ago (Sept. 2, 2025, 11:34 p.m.)
Issued 22 years, 8 months ago (Dec. 31, 2002)
Published 22 years, 8 months ago (Dec. 31, 2002)
Published Online 22 years, 8 months ago (Dec. 31, 2002)
Published Print 22 years, 8 months ago (Jan. 1, 2003)
Funders 0

None

@article{Jenkinson_2002, title={Fast, automated, N‐dimensional phase‐unwrapping algorithm}, volume={49}, ISSN={1522-2594}, url={http://dx.doi.org/10.1002/mrm.10354}, DOI={10.1002/mrm.10354}, number={1}, journal={Magnetic Resonance in Medicine}, publisher={Wiley}, author={Jenkinson, Mark}, year={2002}, month=dec, pages={193–197} }